    The TCC-100/100I series RS-232 to RS-422/485 converters increase networking capability by extending the RS-232 transmission distance. Both converters have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, external terminal block for power, and optical isolation (TCC-100I and TCC-100I-T only). The TCC-100/100I series converters are ideal solutions for converting RS-232 signals to RS-422/485 in critical industrial environments.
    Features and Benefits
    RS-232 to RS-422 conversion with RTS/CTS support
    RS-232 to 2-wire or 4-wire RS-485 conversion
    2 kV isolation protection (TCC-100I)
    Wall- and DIN-rail mounting
    Plug-in terminal block for easy RS-422/485 wiring
    LED indicators for power, Tx, Rx
    Wide temperature range model available (-40 to 85°C)

    RS-232 Side
    Connector
    DB9 female
    Signals
    TxD, RxD, RTS, CTS, GND

    RS-422/485 Side
    Connector
    Terminal Block
    Signals
    (interface selected by DIP switch)
    RS-422: TxD+, TxD-, RxD+, RxD-, RTS, CTS, GND
    RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
    RS-485-2w: Data+, Data-, GND
    RS-485 Data Direction Control
    ADDC® (Automatic Data Direction Control)

    Serial Communication
    Baudrate
    50 bps to 921.6 kbps
    Optical Isolation
    2 kV (TCC-100I/100I-T)

    Physical Characteristics
    Housing
    Metal
    Dimensions
    67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
    Weight
    148 g (0.33 lb)

    Environmental Limits
    Operating Temperature
    Standard Models: -20 to 60°C (-4 to 140°F)
    Wide Temp. Models: -40 to 85°C (-40 to 185°F)
    Storage Temperature
    -40 to 85°C (-40 to 185°F)
    Ambient Relative Humidity
    5 to 95% (non-condensing)

    Power Requirements
    Source of Input Power
    Power input jack
    Input Voltage
    12 to 48 VDC
    Input Current
    TCC-100/100-T: 85 mA @ 12 VDC
    TCC-100I/100I-T: 150 mA @ 12 VDC
    Voltage Reversal Protection
    Protects against V+/V- reversal
    Overcurrent Protection
    Protects against two signals shorted together

    Standards and Certifications
    Safety
    UL 60950-1
    EMC
    EN 55032/24
    EMI
    CISPR 32, FCC Part 15B Class B
    EMS
    EN 61000-4-2 (ESD): Contact: 4 kV; Air: 8 kV
    EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m
    EN 61000-4-4 (EFT): Power: 1 kV; Signal: 0.5 kV
    EN 61000-4-5 (Surge): Power: 1 kV
    EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m
    EN 61000-4-8 (PFMF)
    Green Product